For the ultimate in micro-weighing performance choose Sartorius. The SE2
ultra-microbalance delivers an incredible full resolution of 21 million digits,
with a capacity of 2.1g and 0.1 µg readability ( that's 0.0000001 grams
). Stabilize readings within an ultra fast 10 seconds, for maximum
time savings with each weighing operation. Both the Sartorius SE2 and
ME5 microbalances feature the EUREKA® air buoyancy correction software,
allowing true mass measurement and compensation for fluctuations in air density.
Built-in software simplifies backweighing, and enable fast, error-free storage
of tare weights, initial sample weights and calculation of the amounts backweighed
in any order you choose for as many as 50 samples.
Sartorius SE2 is a premium microbalance to meet the highest requirements when
it’s a matter of obtaining fast and exceptionally accurate results. Achieve
maximum performance when used for inspection, measuring and test equipment within
a quality system. The following features make your quality assurance procedures
much easier: SQmin function: displays the allowable minimum sample weight according
to the United States Pharmacopoeia (must
be activated can calculated); Fully automatic calibration and adjustment
feature, isoCAL; ISO/GLP-compliant recording; Input capability for alphanumeric
sample IDs; and more.
When you really have a weighing application there really is only one manufacturer
to consider - SARTORIUS. Sartorius is a German company and maker of some
of the world's finest balances since 1871 when they introduced the world's first
pharmaceutical balance. Only Sartorius shatters the limits when "the
Guinness Book of World Records" listed the Sartorius Model 4108 as the
most accurate balance in the world. Sartorius has been proving their trustworthiness
thanks to their top-of-the-line technology that ensures maximum accuracy.
Sartorius products are manufactured with ISO9001 standards and have the CE mark.
Sartorius' excellent reputation and image in the technologically sophisticated
field of weighing balances make them a global leader.
Adaptation
to ambient conditions & applications requirements
By
selection of 1 of 4 optimized filter levels
Display
Update
0.2 - 0.4 seconds (depending on filter level)
Operating
Temperature
5°
C to 40 ° C
(41° F to 104° F)
85% RH or less
Sensitivity
Drift
(5°-40°C/41°F-104°F)
±
1 ppm / °C
Pan
Size (mm / in)
ø
20 mm / 0.8 in
Draft
Shield Height
122
mm / 4.8 in
Chamber
Size (inches)
ø
3.3" x 4.8" high
Chamber
Opening(inches)
2.4"
x 1.8"
Electronics
Unit:WxDxH
9.9"
x 12.6" x 4.1"
Deviation
of the readout when balance is tilted 1:1,000
±
3 µg
Selectable
Weight Units
g,
kg, ct, lb, oz, ozt, tlh, tls, tlt, GN, dwt, mg, /lb, tlc, mom, K, tol,
bat, MS
Selectable Application Programs
Mass
unit conversion by toggling,"EUREKA" air buoyancy correction
program, SQmin, differential
weighing and backweighing, density determination, tare memory, net total,
weighing in percent, over / under checkweighing (classification and filling)
counting